316 Freeswitch did not find termination point details

From Kolmisoft Wiki
Revision as of 12:35, 6 October 2016 by Nerijuss (talk | contribs)
Jump to navigationJump to search

Hangupcause Code - 316. Freeswitch did not find termination point details

This error happens when FreeSwitch is asked to dial specific termination point, but FreeSwitch doesn't have any details about this termination point.

How to solve this problem:

  • Check if /tmp/m2 directory has 777 permisions
  • Check if /var/log/m2/m2_freeswitch_devices.log is updated when termination point is created or updated via GUI
  • Check if /var/log/m2/m2_freeswitch_devices.log show any errors. If everything is OK, then log should end with "Job complete. TP: X, GW: Y configured.". If this line is not present, then something is wrong.
  • Even if log does not show errors, manually execute /usr/local/m2/m2_freeswitch_devices and check if it crashes.

Report this issue to developers