316 Freeswitch did not find termination point details
From Kolmisoft Wiki
Jump to navigationJump to search
Hangupcause Code - 316. Freeswitch did not find termination point details
This error happens when FreeSwitch is asked to dial specific termination point, but FreeSwitch doesn't have any details about this termination point.
How to solve this problem:
- Check if /tmp/m2 directory has 777 permisions
- Check if /var/log/m2/m2_freeswitch_devices.log is updated when termination point is created or updated via GUI
- Check if /var/log/m2/m2_freeswitch_devices.log show any errors. If everything is OK, then log should end with "Job complete. TP: X, GW: Y configured.". If this line is not present, then something is wrong.
- Manually execute /usr/local/m2/m2_freeswitch_devices and check if it crashes.
Report this issue to developers