Line 18: | Line 18: | ||
* '''IP Address''' – Device IP address (IP ranges and subnets are accepted). | * '''IP Address''' – Device IP address (IP ranges and subnets are accepted). | ||
* '''Port''' – Device Port. | * '''Port''' – Device Port. | ||
* '''Dynamic IP''' – Allow Origination Point Authentication with Registration. More information [http://wiki.kolmisoft.com/index.php/M2_Dynamic_Origination_Point_Authentication here] | |||
<br><br> | <br><br> | ||
Revision as of 09:54, 20 August 2019
General
- Accountcode – the unique ID of the device in the system.
- Description – for informational purposes.
- Type – what type of device it is.
- Ringing Timeout – allows to limit the ringing duration in seconds. Leave 0 for unlimited. Minimal value is 10 seconds.
- Call Timeout – allows to limit answered call billsec. Leave 0 for unlimited.
Servers
- Server – allows to choose server in multiple servers system.
Authentication
IP Authentication:
- IP Address – Device IP address (IP ranges and subnets are accepted).
- Port – Device Port.
- Dynamic IP – Allow Origination Point Authentication with Registration. More information here
Origination Point
All the information about these settings you can find – M2 Origination Points
Termination Point
All the information about these settings you can find – M2 Termination Points
CallerID
A CallerID consists of two parts: Name and Number. The "Number" part is transferred by default by all technologies (GSM, PSTN, SIP etc), but the "Name" part is transferred only by some. The number you see on your mobile phone when someone is calling you is the "Number" part.
- Name – the "Name" part of the CallerID.
- Number – the "Number" part of the CallerID. Only numerical values can be entered in this field.
NOTE: if you leave these fields empty, the user can set the CallerID name by himself. Usually it is not advisable to allow the user do it on his own. If CallerID number field is empty, system will take device username as CallerID number (if device is username/password authenticated).
- Random Number from Number Pool – This functionality gives you an ability to send different caller number on each Call. More information: Number Pool.
- Unknown - This option lets you set CallerID number to unknown.
Codecs
Choose the codecs your provider uses.
NOTES:
- If the Provider and the Device do not have similar codecs, no call can be established.
Advanced
- Grace Time - if call duration is less than Grace Time, it will not be accounted.
- Accept calls from any port – ignore the port number where request came from.
- Custom SIP Header - adds custom header to SIP request. Format is header: value (for example x-My-Custom-Header: my value)
- Limit up to (number) calls, during (number) seconds – allows to set calls per second limit in some period.
- Disconnect Code Changes – This functionality lets you to change one Hangup Cause Code into another. More information: Disconnect Code Changes.
- Ignore SIP 183 without SDP - SIP 183 (session progress) without SDP causes fake ring to be sent to originator. This setting allows to ignore SIP 183 without SDP and avoid fake ring.